Sign In Logout View CartMy Account / Order StatusHelp

Join our mailing list!



(Your shopping cart is empty)
You are here: Home > ACCESSORIES
Choose a sub category:
DM6 DM660
DM MC6 EP MC6
Air Valves Chamber Caps
Electrodes Filling Syringes
Circulating Water Bath
Sort By:
Page of 1  
Two Syringes With Filling Needles For Using Chamber - FNS15-2 Filling Needle For Using Chamber - FN15 P2020-S Electrode Set



Two Syringes With Filling Needles For Using Chamber - FNS15-2 Filling Needle For Using Chamber - FN15 P2020-S Electrode Set
2 Syringes with soft-tipped 15 gauge needles for filling and emptying EasyMount chambers. Soft-tipped 15 gauge needle for filling and emptying EasyMount chambers.
Includes:
2 sintered Ag/AgCl pellet electrodes for voltage sensing (black)
2 Ag wire electrodes for current passing (white)
8 electrodes tips.
 

Related: 
Manual                   
Files                   
Coming Soon
 
 
P2020-VS Electrode Set P2020-IS Electrode Set DM6 Six Channel Dummy Membrane for VCC MC6



P2020-VS Electrode Set P2020-IS Electrode Set DM6 Six Channel Dummy Membrane for VCC MC6
Includes:
Includes 4 sintered Ag/AgCl pellet electrodes for voltage sensing (black)
8 electrodes tips.
Includes: 
4 Chloride Ag wire electrodes for current passing for current passing (white)
8 electrodes tips.
DM6 Six Channel Dummy Membrane for VCC MC6


The DM6 contains six individual electronic equivalents of an epithelial tissue (i.e., - dummy membrane) that connect to the VCC MC6 via a flat ribbon cable. This device is a convenient tool for learning the features of the VCC MC6 without setting up an experiment and it provides a mechanism for verifying the operating condition of the instrument when problems are encountered during an experiment.

Chamber Caps For The Ussing Chambers: P2300-Cap 20 Electrode Tips 50 Electrode Tips



Chamber Caps For The Ussing Chambers P2023-20 Electrode Tips P2023-50 Electrode Tips
Set of two caps with sampling port for EasyMount chambers. Prevents small droplets splattering caused by aeration. Recommended when radioisotopes or toxic chemicals are used in the chambers.
Spare electrode tips for P2020 Ag/AgCl Electrodes.

 

Available in bags of 20, 50 and 100 tips.
Spare electrode tips for P2020 Ag/AgCl Electrodes.

 

Available in bags of 20, 50 and 100 tips.
100 Electrode Tips Electrode lead set- P2024-36 Dual air control valve - P2060



P2023-100 Electrode Tips Electrode lead set - P2024-36 Dual air control valve - P2060
Spare electrode tips for P2020 Ag/AgCl Electrodes.

 

Available in bags of 20, 50 and 100 tips.
36" Long Custom Electrode Lead Set

(2 mm pin to 1 mm gold socket, 4 individual leads in one cable assembly)

Dual air control valve:

Includes 2 needle valves in an aluminum housing. Mounts on EasyMount chamber stands.
DM660 Single Channel Dummy Membrane DM MC6 Single Channel Electrode Input Module and Dummy Membrane EP MC6 Electrode Input Panel for VCC MC6



DM660 Single Channel Dummy Membrane DM MC6 Single Channel Electrode Input Module and Dummy Membrane EP MC6 Electrode Input Panel for VCC MC6

DM660 Single Channel Dummy Membrane


 


The DM660 is an electronic dummy membrane used to simulate an Ussing experiment. It is useful both in verifying the function of the voltage/current clamp and as a learning aid. This device is compatible with the VCC600.

DM MC6 Single Channel Electrode Input Module and Dummy Membrane


The DM_MC6 is an input device for connecting voltage and current electrodes to the VCC MC2, VCC MC6, and VCC MC8 instruments. The DM MC6 is a small, shielded unit that can be mounted close to individual Ussing chambers and is recommended for use with both our EasyMount Ussing Chamber Systems or for classical Ussing chamber systems. Each DM MC6 also contains a single channel “dummy membrane” for use in testing the the functionality of voltage/current clamp.


Input jacks: 2 mm pin tip. Connection to voltage/current clamp: choice of 4’ or 7’ shielded cable with modular plugs. One DM MC6 is required for each clamp channel.

EP MC6 Electrode Input Panel for VCC MC6

This six channel black anodized aluminum electrode input panel is designed to interface directly with the 6-channel vertical diffusion chamber system now owned by Harvard Apparatus as purchased from Navicyte, Inc. (formerly Precision Instruments Design) or Corning/CoStar. The EP MC6 mounts directly behind the heat block and in front of the air valve manifold. Short electrode leads (P/N P2024, not included) connect current and voltage electrodes to the pintip input jacks. Connection to the VCC MC6 is by way of a flat cable assembly (included).
Circulating Water Bath 115V/60HZ/1Phase/9Amps Circulating Water Bath 230V/50HZ/1Phase/12Amps


Circulating Water Bath 115V/60HZ/1Phase/9Amps Circulating Water Bath 230V/50HZ/1Phase/12Amps
Circulating Temperature Control Water Bath 115V/60HZ/1Phase/9Amps
The Thermo Scientific NESLAB EX-7 7 liter heating baths offer great value for either external circulation or in-bath applications:
· Simple to use controls available with the Digital One controller
· Meet many of your application needs with a wide temperature range
· Autorefill option ensures that the bath remains operational even at high temperatures
Circulating Temperature Control Water Bath 230V/50HZ/1Phase/12Amps
The Thermo Scientific NESLAB EX-7 7 liter heating baths offer great value for either external circulation or in-bath applications:
· Simple to use controls available with the Digital One controller
· Meet many of your application needs with a wide temperature range
· Autorefill option ensures that the bath remains operational even at high temperatures
   
 
Ussing Chamber Ussing Chambers Physiologic Instruments

 About Us
 Privacy Policy
 Send Us Feedback
 
Company Info | Support | Product Index | Category Index | Help | Terms of Use | Sitemap
Copyright © 2007- 2008- 2009 Ussing Chamber Ussing Chambers Physiologic Instruments. All Rights Reserved.

Physiologic Instruments Inc. | Voltage Current Clamps | Ussing Chambers | UssingChamber.com | EasyMount Systems | Electrodes | Dr. Hans Ussing | The Ussing Chamber | Acquire & Analyze | VCC 600 | VCC MC2 | VCC MC6 | VCC MC8 | EM-CSYS-2 | EM-CSYS-4 | EM-CSYS-6 | EM-CSYS-8 | Chambers For Rat Colon (Intestinal Tissue) | Low Volume Ussing Chambers | Contact Us | About Physiologic Instruments | Ussing Chamber Systems

Refinance Shopping Cart Software